Справочник Пользователя для Intel SE7520JR2

Скачать
Страница из 225
Intel® Server Board SE7520JR2 
Functional Architecture 
Revision 1.0 
 
 
C78844-002 
41
status of the extended memory test is displayed on the console.  The status of base and 
extended memory tests are also displayed on an LCD control panel if present.  
The extended memory test is configured using the BIOS Setup Utility.  The coverage of the test 
can be configured to one of the following:  
• 
Test every location (Extensive) 
• 
Test one interleave width per kilo-byte of memory (Sparse) 
• 
Test one interleave width per mega-byte of memory (Quick).   
 
The “interleave width” of a memory subsystem is dependent on the chipset configuration.  By 
default, both the base and extended memory tests are configured to the Disabled setting.  The 
extended memory test can be aborted by pressing the <Space> key during the test. 
3.3.5 Memory 
Monitoring 
Both the baseboard management controller and BIOS provide support for memory inventory, 
memory failure LEDs, and failure/state transition events. Memory monitoring features are 
supported differently depending on which level of server management is used.  The following 
table shows how each feature is supported by management level. 
Table 6: Memory Monitoring Support by Server Management Level 
Memory Feature 
On-board 
Professional 
Advanced 
Inventory No 
Yes 
Yes 
Correctable Error Reporting 
No 
Yes 
Yes 
Uncorrectable Error Reporting 
Yes 
Yes 
Yes 
 
With either Professional or Advanced IMMs installed, the Sahalee BMC maintains one sensor 
per DIMM. The sensor is IPMI type 21h, Slot/Connector. The Sahalee BMC directly detects the 
presence or absence of each DIMM and records this in offset 2 of these sensors. 
DIMM failure can be detected at BIOS POST or during system operation. POST detected DIMM 
failures or mis-configuration (incompatible DIMM sizes/speeds/etc) cause the BIOS to disable 
the failed/affected DIMMs and generate IPMI SEL events, which are sent to the BMC in use.  
In addition, using Professional or Advanced IMMs, the BIOS communicates this failure to the 
Sahalee BMC so that it can be incorporated in the BMC’s DIMM sensor state. DIMM presence 
and failure states are stored persistently by the Sahalee BMC. 
In all management levels, the BIOS is responsible for DIMM FRU LED management and 
illuminates the LEDs associated with failed or disabled DIMMs.  
Correctable memory errors are non-critical errors that do not cause the system to fail. They are 
detected by the BIOS and are logged as IPMI SEL events when either the Professional or 
Advanced IMMs are installed. Logging is throttled by error frequency. If more than a certain 
number of correctable errors occur in an hour, logging is turned off.