Design and Environmental Specifications 
Intel® Server Boards S5000PSL and S5000XSL TPS 
 
  
Revision 
1.2 
Intel order number: D41763-003 
70 
7.  Power down and remove the AC power cord. 
8.  Open the server chassis. 
9.  Move jumper from the enabled position, covering pins 2 and 3 to the disabled position, 
covering pins 1 and 2. 
10. Close the server chassis. 
11. Reconnect the AC cord and power up the server. 
Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the 
enabled position. The server should never be run with the BMC Force Update jumper set in this 
position. This jumper setting should only be used when the standard firmware update process 
fails. This jumper should remain in the default / disabled position when the server is running 
normally.  
6.3  BIOS Select Jumper 
The jumper block at J1C3, located at the left of PCI-X* slot 1, is used to select which BIOS 
image the system will boot to. Pin 1 on the jumper is identified with a ‘▼’. This jumper should 
only be moved if you want to force the BIOS to boot to the secondary bank, which may hold a 
different version of BIOS.  
The rolling BIOS feature of the server board will automatically alternate the boot BIOS to the 
secondary bank if the BIOS image in the primary bank is corrupted and cannot boot.