Справочник Пользователя для Intel S5000PSL

Скачать
Страница из 120
Design and Environmental Specifications 
Intel® Server Boards S5000PSL and S5000XSL TPS 
 
  
Revision 
1.2 
 
6. Jumper 
Blocks 
The server board has several 3-pin jumper blocks that can be used to configure, protect, or 
recover specific features of the server board.  
Pin 1 on each jumper block can be identified by the following symbol on the silkscreen: ▼ 
AF000422
3
2
CMOS Clear
3
2
Password Clear
J1E3
J1D1
Disable
Enable
3
2
BMC Force Update
J1D2
Disable
Enable
BIOS Bank Select
J1C3
3
2
Force Lower
Bank
Normal 
Operation
(default)
Protect
Clear
 
Figure 17. Jumper Blocks (J1C3, J1D1, J1D2, J1E32) 
Table 35. Server Board Jumpers (J1C3, J1D1, J1D2, J1E3) 
Jumper Name 
Pins  
System Results 
1-2 
Intel order number: D41763-003 
68 
If these pins are jumper the system will boot from an alternate BIOS image. 
J1C3: BIOS Bank 
Select 
2-3 
System is configured for normal operation. (Default) 
1-2 
These pins should have a jumper in place for normal system operation. (Default) 
J1D1: CMOS Clear 
2-3 
If these pins are jumpered, the CMOS settings will be cleared immediately. These pins 
should not be jumpered for normal operation 
1-2 
These pins should have a jumper in place for normal system operation. (Default) 
J1D2: Password 
Clear 
2-3 
If these pins are jumpered, administrator and user passwords will be cleared 
immediately. These pins should not be jumpered for normal operation. 
1-2 
BMC Firmware Force Update Mode – Disabled (Default) 
J1E3: BMC Forced 
Update 
2-3 
BMC Firmware Force Update Mode – Enabled