Справочник Пользователя для Intel S5000PSL
Design and Environmental Specifications
Intel® Server Boards S5000PSL and S5000XSL TPS
Revision
1.2
6. Jumper
Blocks
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board.
recover specific features of the server board.
Pin 1 on each jumper block can be identified by the following symbol on the silkscreen: ▼
AF000422
3
2
CMOS Clear
3
2
Password Clear
J1E3
J1D1
Disable
Enable
3
2
BMC Force Update
J1D2
Disable
Enable
BIOS Bank Select
J1C3
3
2
Force Lower
Bank
Normal
Operation
(default)
Protect
Clear
Figure 17. Jumper Blocks (J1C3, J1D1, J1D2, J1E32)
Table 35. Server Board Jumpers (J1C3, J1D1, J1D2, J1E3)
Jumper Name
Pins
System Results
1-2
Intel order number: D41763-003
68
If these pins are jumper the system will boot from an alternate BIOS image.
J1C3: BIOS Bank
Select
Select
2-3
System is configured for normal operation. (Default)
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D1: CMOS Clear
2-3
If these pins are jumpered, the CMOS settings will be cleared immediately. These pins
should not be jumpered for normal operation
should not be jumpered for normal operation
1-2
These pins should have a jumper in place for normal system operation. (Default)
J1D2: Password
Clear
Clear
2-3
If these pins are jumpered, administrator and user passwords will be cleared
immediately. These pins should not be jumpered for normal operation.
immediately. These pins should not be jumpered for normal operation.
1-2
BMC Firmware Force Update Mode – Disabled (Default)
J1E3: BMC Forced
Update
Update
2-3
BMC Firmware Force Update Mode – Enabled