DISK DRIVE OPERATION 
 
SpinPoint V40 Product Manual 
86
 
6.6.3 Non-Data 
Commands 
 
This class includes: 
 
  Check Power Mode (98h,E5h) 
  Flush Cache (E7h) 
  Execute Drive Diagnostic (DRDY=x) (90h) 
  Idle (97h,E3h) 
  Idle Immediate (95h,E1h) 
  Initialize Drive Parameters (DRDY=x) (91h) 
  NOP (00h) 
  Read Native Max Address (F8h) 
  Read Verify Sector(s) (40h) 
  Recalibrate (1Xh) 
  Seek (7Xh) 
  Set Features (EFh) 
  Set Max Address (F9h) 
  Set Multiple Mode (C6h) 
  Sleep (99h,E6h) 
  SMART Disable Operation 
  SMART Enable/Disable Autosave 
  SMART Enable Operation 
  SMART Execute Off-line Immediate 
  SMART Return Status 
  Standby (96h,E2h) 
  Standby Immediate (94h,E0h) 
 
 
Execution of these commands involves no data transfer. 
 
a)  The host writes any required parameters to the Features, Sector Count, Sector Number, Cylinder and 
Drive/Head registers. 
 
b)   The host writes the command code to the Command register. 
 
c)   The drive sets BSY. 
 
d)   When the drive has completed processing, it clears BSY and asserts INTRQ. 
 
e)   The host reads the Status register. 
 
f)   The drive negates INTRQ.