Maintenance Object Repair Procedures
Page 10-388
DATA-CHL (Network Control Data Channel)
10
Journal Printer Links
1. Issue the
status journal-link wakeup-log
and
status journal-link
pms-log
commands to see if one or both of these Journal Printer Links
have been established. If the Link State field is "Up" for either of these,
then that Journal Printer Link may be using one of the Network Control
Data Channels (DATA-CHLs).
then that Journal Printer Link may be using one of the Network Control
Data Channels (DATA-CHLs).
2. Issue the
display system hospitality
command and note the values in
the Extension of Journal/System Printer and Extension of PMS Log Printer
fields. If either of these values are extensions, then that Journal Printer Link
is using one of the Network Control Data Channels (DATA-CHLs).
fields. If either of these values are extensions, then that Journal Printer Link
is using one of the Network Control Data Channels (DATA-CHLs).
3. For each of the extensions in the Extension of Journal/Schedule Printer
and Extension of PMS Log Printer fields, issue the
status data-module
<ext>
command using the extension. Note the value in the Connected
Ports field of the resulting form. If there is a port value in the field, then the
indicated port is a Network Control Data Channel (DATA-CHL).
indicated port is a Network Control Data Channel (DATA-CHL).
4. Issue the
list data-module
command, locate each port indicated in the
Connected Ports fields, and determine if that port has a "type" value of
"netcon." If so, then there is a Journal Printer Link over that DATA-CHL.
"netcon." If so, then there is a Journal Printer Link over that DATA-CHL.
PMS Link
1. Issue the
status pms-link
command to see if a PMS Link has been
established. If the Link State field is "Up," the PMS Link may be using one
of the Network Control Data Channels (DATA-CHLs).
of the Network Control Data Channels (DATA-CHLs).
2. Issue the
display system hospitality
command and note the value in the
Extension of the PMS field. If this value is an extension, the PMS Link is
using one of the Network Control Data Channels (DATA-CHLs).
using one of the Network Control Data Channels (DATA-CHLs).
3. For the extension in the Extension of PMS field, issue the
status
data-module <ext>
command using the extension. Note the value in the
Connected Ports field of the resulting form. If there is a port value in the
field, the indicated port is a Network Control Data Channel (DATA-CHL).
field, the indicated port is a Network Control Data Channel (DATA-CHL).
4. Issue the
list data-module
command, locate the port indicated in the
Connected Ports field, and determine if that port has a "type" value of
"netcon." If so, there is a PMS Link over that DATA-CHL.
"netcon." If so, there is a PMS Link over that DATA-CHL.