Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-389
DATA-CHL (Network Control Data Channel)
10
Error Log Entries and Test to Clear Values
Notes:
a. This error type indicates that the circuit pack has been removed or has
been insane for more than 11 minutes. To clear the error, reinsert or
replace the circuit pack.
replace the circuit pack.
b. In a system with the duplication option, a busyout of the DATA-CHL is
preserved across an SPE interchange. When an SPE interchange occurs,
and the DATA-CHL is busied out, the busyout state is transferred to the
corresponding DATA-CHL on the new active SPE while the DATA-CHL on
the former active SPE is released.
and the DATA-CHL is busied out, the busyout state is transferred to the
corresponding DATA-CHL on the new active SPE while the DATA-CHL on
the former active SPE is released.
System Technician-Demanded Tests:
Descriptions and Error Codes
Descriptions and Error Codes
There are two system technician test commands that include the Network Control
Data Channels (DATA-CHLs). The
Data Channels (DATA-CHLs). The
test data-module <ext> [short | long]
command tests the single DATA-CHL that has the extension specified by <ext>.
The
The
test network-control [a | b] [short | long]
command tests each
administered DATA-CHL that resides on the Network Control circuit pack in the
specified carrier.
specified carrier.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
Table 10-106.
Network Control Data Channel Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
(a)
0
Any
Any
Any
test data-module <ext> sh r 1
1
Any
Local Loop Back Test
(#111)
(#111)
MINOR
ON
test data-module <ext> sh r 3
18 (b)
0
busyout data-module
<ext>
<ext>
WARNING
OFF
release data-module <ext>
130
None
WARNING
ON
test data-module <ext> sh
257
Any
Remote Maintenance
Loop Around Test
(#109)
Loop Around Test
(#109)
MINOR
ON
test data-module <ext> sh r 5
513
Any
Crosstalk Test (#110)
MINOR
ON
test data-module <ext> sh r 3
769
Any
Dual Port RAM Test
(#108)
(#108)
MINOR
ON
test data-module <ext> l r 3