Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-424
DC-POWER
10
c. Refer to “RING-GEN” for a description of this test.
NOTE:
Tests #117 and #118 only show up in the test sequence if there is a TN768
Tone-Clock circuit pack in the port network being tested.
Tests #117 and #118 only show up in the test sequence if there is a TN768
Tone-Clock circuit pack in the port network being tested.
Single-Carrier Cabinet Power Query Test (#79)
This test queries the Maintenance/Tape Processor (in a PPN) or the EPN
Maintenance circuit pack (in an EPN) about the status of the power in a
single-carrier cabinet system. This test can only detect power problems in
carriers in the Port Network for which the Carrier Port Power Unit is physically
present.
Maintenance circuit pack (in an EPN) about the status of the power in a
single-carrier cabinet system. This test can only detect power problems in
carriers in the Port Network for which the Carrier Port Power Unit is physically
present.
Table 10-120.
TEST #79 Single-Carrier Cabinet Power Query Test
Error
Code
Code
Test
Result
Description/ Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1minute intervals a maximum of 5 times.
2000
ABORT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1minute intervals a maximum of 5 times.
2. If the test continues to ABORT with Error Code 2000, check for system
powering problems with the A cabinet (PPN or EPN). Resolve all
DC-POWER alarms. Then, repeat the test. If the test continues to ABORT
with a 2000 Error Code, resolve all DUPINT (Duplication Interface Circuit
Pack) errors in a PPN for a high or critical reliability system, or MAINT
(EPN Maintenance circuit pack) errors in an EPN. Then, repeat the test.
DC-POWER alarms. Then, repeat the test. If the test continues to ABORT
with a 2000 Error Code, resolve all DUPINT (Duplication Interface Circuit
Pack) errors in a PPN for a high or critical reliability system, or MAINT
(EPN Maintenance circuit pack) errors in an EPN. Then, repeat the test.
2029
ABORT
Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Continued on next page