DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-429
DID-DS1 (DS1 DID Trunk) 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field 
contains the Error Type: 57476, on-hook before wink; 57477, on-hook 
before ready to receive digits; 57485, wink too short for valid signal. 
Escalate the error.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator 
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are 
out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the 
set 
options
 command. If the Minor alarm is not downgraded by the 
set options
 values, the Minor alarm is 
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Direct Inward Dial Trunk Maintenance Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr> 
sh r 1
1 (a)
Any
15 (b)
Any
Port Audit and 
Update Test (#36)
18 (c)
WARNING
OFF
release trunk 
<grp>/mbr>
130 (d)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (e)
57474 
57473
513 (f)
57392
None
MIN/MAJ
2
OFF
769 (g)
57393
None
MIN/MAJ
OFF
1281
Conference Circuit 
Test (#7)
MAJ/MIN/ 
WRN
3
ON
test trunk <grp>/<mbr> l
1537
NPE Crosstalk Test 
(#6)
MAJ/MIN/ 
WRN
ON
test trunk <grp>/<mbr> l
1793 (h)
ON
test board PCSS l
2305(i)
50944
None
MIN/MAJ
OFF
3840 (j)
Port Audit and 
Update Test (#36)