Lucent Technologies R5SI Manual Do Utilizador
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-429
DID-DS1 (DS1 DID Trunk)
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. DS1 Interface circuit pack detects a hardware error. The Aux Data field
contains the Error Type: 57476, on-hook before wink; 57477, on-hook
before ready to receive digits; 57485, wink too short for valid signal.
Escalate the error.
before ready to receive digits; 57485, wink too short for valid signal.
Escalate the error.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
test description and follow the recommended procedures.
2.
This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
field set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are
out of service, then the alarm will be upgraded to a MAJOR alarm.
3.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set
options
command. If the Minor alarm is not downgraded by the
set options
values, the Minor alarm is
upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
Direct Inward Dial Trunk Maintenance Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test trunk <grp>/<mbr>
sh r 1
sh r 1
1 (a)
Any
15 (b)
Any
Port Audit and
Update Test (#36)
Update Test (#36)
18 (c)
WARNING
OFF
release trunk
<grp>/mbr>
<grp>/mbr>
130 (d)
None
WARNING
ON
test trunk <grp>/<mbr>
257 (e)
57474
57473
57473
513 (f)
57392
None
MIN/MAJ
2
OFF
769 (g)
57393
None
MIN/MAJ
OFF
1281
Conference Circuit
Test (#7)
Test (#7)
MAJ/MIN/
WRN
WRN
3
ON
test trunk <grp>/<mbr> l
1537
NPE Crosstalk Test
(#6)
(#6)
MAJ/MIN/
WRN
WRN
ON
test trunk <grp>/<mbr> l
1793 (h)
ON
test board PCSS l
2305(i)
50944
None
MIN/MAJ
OFF
3840 (j)
Port Audit and
Update Test (#36)
Update Test (#36)