Maintenance Object Repair Procedures 
Page 10-513
DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
DIOD-TRK (DIOD Trunk) [G1.2SE]
Direct Inward and Outward Dial (TN429 DIOD) trunks are 2-wire analog lines to 
the CO which support the following services:
both incoming and outgoing CO calls
DID trunk
DID Trunk and 1-way Outgoing DIOD
The DIOD Trunk circuit pack provides eight ports for loop-start CO. The circuit 
pack is an interface between the 2-wire analog line from the CO and the system’s 
(4-wire) TDM Bus.
LOOP START OPERATION
Idle State - Tip = ground, Ring = CO Battery
A. Outgoing Call
1. PBX Off-Hook (Seize Message): Closes the Tip-Ring Loop
a. CO Response: DC loop current + Dial tone
2. PBX On-Hook (Drop Message): Open Tip-Ring loop, no loop current
a. CO Response: CO goes to idle state (see Note)
B. Incoming Call
1. CO Applies Ringing Voltage
a. PBX Response: Detect ringing current
1.
Where P is the port network number (1 for PPN, 2 for EPN, and 3 for the second EPN); 
C is the carrier designation (for example, A, B, C, D, or E); and SS is the address of the 
slot in the carrier where the circuit pack is located (for example, 01, 02, ...etc.).
2.
A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded 
by the 
set options
 command and that at least 75 percent of the trunks in this trunk 
group are alarmed.
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
DIOD-TRK
MAJOR
2
test port PCSSpp l
DIOD Trunk
DIOD-TRK
MINOR
test port PCSSpp l
DIOD Trunk
DIOD-TRK
WARNING
test port PCSSpp l
DIOD Trunk