DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-515
DIOD-TRK (DIOD Trunk) [G1.2SE] 
10
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. These are in-line errors that have no specific test associated with them. 
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware 
malfunction. Run the Short Test Sequence and investigate associated 
errors (if any).
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the 
set options
 command. If the Minor alarm is not downgraded by the 
set-options
 values, the Minor 
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DIOD Trunk Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear 
Value
0
1
0
Any
Any
Any
test port 
PCSSpp sh r 
1
15 (b)
any
Port Audit Update Test 
(#36)
18
0
busyout trunk 
<grp>/<mbr>
769 (a)
57392
None
MAJ/MIN/
 WRN
2
ON
1537
Dial Tone Test (#0)
MAJ/MIN/
 WRN
2
ON
test port 
PCSS l r 2
1793
Loop Around and 
Conference Test (#33)
MAJ/MIN/
 WRN
2
ON
test port 
PCSS l r 3
2049
NPE Cross Talk Test (#6)
MAJ/MIN/
 WRN
2
ON
test port 
PCSS l r 3
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None