DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-515
DIOD-TRK (DIOD Trunk) [G1.2SE]
10
Hardware Error Log Entries and Test to Clear
Values
Values
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run the Short Test Sequence and investigate associated
errors (if any).
errors (if any).
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
2.
Minor alarms on this MO may be downgraded to warning alarms based on the values used in the
set options
command. If the Minor alarm is not downgraded by the
set-options
values, the Minor
alarm is upgraded to a Major alarm if 75 percent of the trunks in this trunk group are alarmed.
DIOD Trunk Error Log Entries
Error
Type
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Value
0
1
0
Any
Any
Any
test port
PCSSpp sh r
1
PCSSpp sh r
1
15 (b)
any
Port Audit Update Test
(#36)
(#36)
18
0
busyout trunk
<grp>/<mbr>
<grp>/<mbr>
769 (a)
57392
None
MAJ/MIN/
WRN
WRN
2
ON
1537
Dial Tone Test (#0)
MAJ/MIN/
WRN
WRN
2
ON
test port
PCSS l r 2
PCSS l r 2
1793
Loop Around and
Conference Test (#33)
Conference Test (#33)
MAJ/MIN/
WRN
WRN
2
ON
test port
PCSS l r 3
PCSS l r 3
2049
NPE Cross Talk Test (#6)
MAJ/MIN/
WRN
WRN
2
ON
test port
PCSS l r 3
PCSS l r 3
2561 (a,d)
57345
None
2817 (a,e)
57393
None
3073 (a,c)
57376
None
3073 (a,c)
57424
None
3585 (a,c)
57424
None