Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-645
ETR-PT (Enhanced Tone Receiver Port) 
10
ETR-PT (Enhanced Tone Receiver 
Port)
NOTE:
Replacing the tone/clock circuit pack requires a special procedure which is 
described in the documentation for TONE-BD. That section also describes 
the LED display for this board.
The TN2182 is a combined Tone Generator/Tone Detector board. It provides 8 
Enhanced Tone receiver (ETR) ports. Each of these ports provides the functions 
previously found individually on DTMR-PTs, GPTD-PTs and CLAS-PTs ports. 
Thus each port on the TN2182 may be used for any tone detection function that 
was previously done by TN748, TN420 or TN744 Tone detection boards.
The TN2182 provides Mu-law or A-law tone detection capability.
Since the TN2182 also provides Tone/Clock function only one (or two if your 
system is duplicated) TN2182 circuit packs may be present in a port network. 
Thus if more tone detection resources are needed, the additional resources must 
be provided by TN748, TN420 or TN744 circuit packs.
1.
P is the port network number (1 for PPN, 2 - 3 for EPNs). C is the carrier designation 
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 
21).
MO Name As 
It Appears in 
Alarm Log
Alarm 
Level
Initial System 
Technician 
Command to Run
1
Full Name of MO
ETR-PT(a)
MAJOR
test port PCSSpp sh
Enhanced Tone 
Receiver Port
ETR-PT 
MINOR
test port PCSSpp sh
Enhanced Tone 
Receiver Port
ETR-PT 
WARNING
test port PCSSpp sh
Enhanced Tone 
Receiver Port