DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-668
EXP-INTF (Expansion Interface Circuit Pack) 
10
communicate with the EPN Maintenance circuit pack. MAINT Error 
Type 3329 means the EPN Maintenance circuit pack cannot talk to 
the EPN Expansion Interface circuit pack in the A carrier. MAINT 
Error Type 3585 means the EPN Maintenance circuit pack cannot 
talk to the EPN Expansion Interface circuit pack in the B carrier.
5. Synchronization (SYNC) maintenance may have detected an 
inability of the Active Expansion Interface Link to provide 
synchronization between cabinets. Examine Error Log for SYNC 
Error Type 2305 with the same approximate time as this error.
x. Error Type 11000 with an Aux value of 2 appears when a system 
technician-demanded Expansion Interface Link Switch is issued. No 
further action is required.
y. Error Type 11000 with an Aux value of 3 appears when a scheduled EI 
Link Switch has occurred. No further action is required.
z. Error Type 11000 with an Aux value of 4 appears when an Expansion 
Interface Link Switch has occurred due to a Special EPN recovery 
strategy. The software has forced an Expansion Interface switch because 
the new Expansion Interface Link contains new features which support 
EPN recovery in case of a bad tone/clock board. This error code appears 
when there is a periodic/scheduled tone/clock switch.
aa. Error Type 11000 with an Aux value of 5 appears when the system has 
detected an excessive backup of traffic on the Active Expansion Link. This 
condition may have been due to communication difficulties on the 
Expansion link. To restore normal service, the system switched Expansion 
Links to the link identified in the Error Type 11000 with an Aux Data value 
of 5. Error Type 10004 should be present against the Expansion Interface 
circuit pack that reported the traffic congestion.
ab. Error type 11000 with an Aux value of 8 indicates that the EI link was 
switched as part of the recovery action taken by EPN-SNTY. This error 
should be accompanied by EPN-SNTY error 8802 0. If EPN-SNTY error 
9902 0 is also present, this indicates that the switching of the EI link was 
the recovery action that restored sanity to the EPN. In this case, the fault 
was with the link that was switched away from. The relevant EIs and 
connections should be tested and examined to determine the cause of the 
problem. Look for EPN-SNTY errors in the error log, and refer to the EPN 
Sanity Audit (EPN-SNTY) section for more details.
ac. Error Type 11001 occurs when an Expansion Link switch was attempted 
but for unknown reasons could not be completed.
Expansion Interface LED Usage
The EI circuit pack has the standard red, green, and yellow LEDs. The red and 
green LEDs have the traditional use, where red means some alarm condition and 
green indicates maintenance testing in progress. The yellow LED is used to