DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-669
EXP-INTF (Expansion Interface Circuit Pack) 
10
provide useful visual status information. The state of the yellow LED is very 
important when executing the EI Manual Loop Back Procedure previously 
described. 
Upon power-up, the TN776 red LED comes on and off, followed by the yellow 
LED coming on solid. The TN570 red and green LEDs comes on and off. The 
yellow LED remains off.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below. By 
clearing error codes associated with the 
Expansion Interface Reset Test,
 for 
example, you may also clear errors generated from other tests in the testing 
sequence.
Expansion Interface Neighbor Query Test (#237)
The Expansion Interface Neighbor Query Test is a request to an EI circuit pack to 
determine if it has established communication with the EI circuit pack on the 
opposite end of the fiber.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Expansion Interface Reset Test (#336)
D
Expansion Interface Fiber Out-of-Frame Query 
Test (#238)
X
X
ND
Expansion Interface Lightwave Transceiver 
Interface Loop Around Test (#242)
X
D
Expansion Interface Control Channel Test (#316)
X
X
ND
Expansion Interface Neighbor Query Test (#237)
X
X
ND
Expansion Interface Local Loop Around Test 
(#240)
X
X
ND
Expansion Interface 2-Way Transmission Test 
(#241)
X
X
ND
TN570 Expansion Interface Packet Interface Test 
(#589)
X
X
ND