M/T-PKT (Maintenance/Test Packet Bus Port) 
10
Packet Bus Port Health Inquiry Test (#567)
This test verifies that the Packet Bus fault detection maintenance function of the 
Maintenance/Test Packet Bus Port is functioning properly. This is done by having 
the Maintenance/Test Packet Bus Port perform a self-test. If this self-test passes, 
then the Packet Bus Port Health Inquiry Test passes. If the self-test fails, or the 
SPE cannot communicate with the Maintenance/Test Packet Bus Port, then the 
test fails.
Table 10-284.
TEST #567 Packet Bus Port Health Inquiry Test 
Error 
Code
Test 
Result
Description/ Recommendation
2000
ABORT
Response to the test request was not received within the 
allowable time period.
2100
ABORT
System resources necessary to run this test are not 
available.
2500
ABORT
An internal operation failed; the test could not be 
completed.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
2059
FAIL
The Maintenance/Test Packet Bus Port has reported a 
failure of the on-board self-test.
2060
FAIL
The Maintenance/Test Packet Bus Port has reported an 
invalid state for the Packet Bus.
2061
FAIL
The SPE cannot communicate with the 
Maintenance/Test Packet Bus Port, but is able to 
communicate with the Maintenance/Test Circuit Pack.
1. Retry the command.
2. If the test continues to fail, replace the 
Maintenance/Test circuit pack and retry the 
command.
3. If the test continues to fail, refer to PKT-BUS 
Maintenance documentation to determine if the 
M/T-PKT failure is being caused by a Packet Bus 
fault.
PASS
The Maintenance/Test Packet Bus Port Packet Bus fault 
detection capability is operating correctly.