Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1148
PR-MAINT (Maintenance Processor [TN790 RISC Systems])
10
MTP Sanity Handshake Test (#106)
This test is a nondestructive test. The MTP Sanity Handshake Test is simply a
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
query from a maintenance process to the MTP. The MTP must reply for the test to
pass.
MTP SAT Loop Around Test (#228)
This test is a nondestructive test. The test places the SAT channel of the MTP into
a loop around mode, and it verifies the data integrity of the channel. Although the
test is nondestructive, it causes loss of keyboard input from the PPN SAT.
a loop around mode, and it verifies the data integrity of the channel. Although the
test is nondestructive, it causes loss of keyboard input from the PPN SAT.
Table 10-340.
TEST #106 MTP Sanity Handshake Test
Error Code
Test
Result
Description/ Recommendation
100
ABORT
The test did not complete within the allowable time period.
1. Retry the command.
1000
ABORT
System software resources required for this test are not available.
1. Retry at 1-minute intervals a maximum of 5 times.
1029 2014
2015 2016
2017 2018
2020 2022
2024 2025
2051
2015 2016
2017 2018
2020 2022
2024 2025
2051
ABORT
Refer to “STBY-SPE” for a description of these error codes.
2000
ABORT
The response to the test request was not received within the allowable
time period.
time period.
2033
ABORT
Internal system error.
1. Repeat the command at 1-minute intervals a maximum of 5 times.
FAIL
The MTP did not respond to the Sanity Handshake Query.
1. Re-enter command with the ‘‘long’’ option.
2. If the test continues to fail, replace the Processor circuit pack.
PASS
The MTP responded to the Sanity Handshake Query.
Continued on next page