Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1185
PROCR (Processor Circuit Pack)
10
■
Divide by zero
■
Single step
■
One byte interrupt instruction.
Processor ROM Checksum Test (#80)
This test is a nondestructive test. The test computes the checksum of the
processor’s bootstrap ROM, and it compares this checksum to a predetermined
value stored within the ROM. A failure of this test indicates corruption of the ROM.
processor’s bootstrap ROM, and it compares this checksum to a predetermined
value stored within the ROM. A failure of this test indicates corruption of the ROM.
Table 10-362.
TEST #77 Processor Software Initiated Interrupt Test
Error
Code
Code
Test
Result
Description/ Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these
error codes.
error codes.
FAIL
The processor did not detect the software interrupt condition. As a result, the
processor executed the incorrect interrupt vector. The system may or may
not continue to operate correctly.
processor executed the incorrect interrupt vector. The system may or may
not continue to operate correctly.
1. Repeat the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, the Processor circuit pack should be
replaced.
!
WARNING:
If the TN786B circuit pack [386 systems only] must be replaced, and if
there is a blank in the Expansion Memory circuit pack slot (that is, in the
slot immediately to the right of the TN786B circuit pack), remove the
blank before removing the circuit pack. Otherwise, the circuit pack
and/or the two connectors that are used to connect the Expansion
Memory circuit pack (if available) might become damaged.
there is a blank in the Expansion Memory circuit pack slot (that is, in the
slot immediately to the right of the TN786B circuit pack), remove the
blank before removing the circuit pack. Otherwise, the circuit pack
and/or the two connectors that are used to connect the Expansion
Memory circuit pack (if available) might become damaged.
PASS
The processor detected the software interrupt condition, and it executed the
correct interrupt vector. The system continues to operate correctly.
correct interrupt vector. The system continues to operate correctly.
Continued on next page