Maintenance Object Repair Procedures 
Page 10-1185
PROCR (Processor Circuit Pack) 
10
Divide by zero
Single step
One byte interrupt instruction.
Processor ROM Checksum Test (#80)
This test is a nondestructive test. The test computes the checksum of the 
processor’s bootstrap ROM, and it compares this checksum to a predetermined 
value stored within the ROM. A failure of this test indicates corruption of the ROM.
Table 10-362.
TEST #77 Processor Software Initiated Interrupt Test 
Error 
Code
Test 
Result
Description/ Recommendation
1029 
2014 
2015 
2016 
2017 
2018 
2020 
2022 
2024 
2025 
2051
ABORT
Refer to STBY-SPE Maintenance documentation for a description of these 
error codes.
FAIL
The processor did not detect the software interrupt condition. As a result, the 
processor executed the incorrect interrupt vector. The system may or may 
not continue to operate correctly.
1. Repeat the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to fail, the Processor circuit pack should be 
replaced.
!
WARNING:
If the TN786B circuit pack [386 systems only] must be replaced, and if 
there is a blank in the Expansion Memory circuit pack slot (that is, in the 
slot immediately to the right of the TN786B circuit pack), remove the 
blank before removing the circuit pack. Otherwise, the circuit pack 
and/or the two connectors that are used to connect the Expansion 
Memory circuit pack (if available) might become damaged.
PASS
The processor detected the software interrupt condition, and it executed the 
correct interrupt vector. The system continues to operate correctly.