DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1298
STRAT-3 (Stratum 3 Clock)] 
10
NOTE:
When looking in the Stratum 3 cabinet, "A" card is on the left and "B" card is 
on the right.
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. In the context of the Stratum 3 clock, an OFF-BOARD alarm occurs when 
there is a DS1 facility problem; otherwise, the alarm is ON-BOARD 
indicating that there is a fault in the Stratum 3 clock or in the connection 
between the Stratum 3 clock and the PBX (Private Branch Exchange) 
switch. If the Stratum 3 clock cannot be referenced, and therefore the 
1.
Composite Clock source refers to the protocol used to electrically transfer timing from 
the Stratum 3 clock to the PBX switch. The Composite Clock source is not relevant to 
Definity Generic 1.1.
1.
Run the Short Test Sequence. Refer to the appropriate test description and follow the recommended procedures.
Stratum 3 Clock Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test synchronization r 4
1 (d)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (e)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
OFF
test synchronization r 4
257 (c)
None
WARNING
ON
513 (f)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
ON
test synchronization r 4
769 (g)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR
ON
test synchronization r 4
1025 (h)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1281 (i)
Any
Stratum 3 Clock 
Alarm Query (#649)
MINOR/ MAJOR(a)
ON
test synchronization r 4
1537 (b)
none
MINOR/ MAJOR(a)
ON