Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-58
change synchronization 
8
For the following example, the command that was entered is "change 
synchronization" and "4" was entered in the stratum field.
For the following example, the command that was entered is "change 
synchronization" and "3" was entered in the stratum field.
Feature Interactions
A DS1 interface or a UDS1 board that has been selected as either a primary or 
secondary synchronization source cannot be removed on the DS1 circuit pack 
administration form or the regular circuit pack administration form.
Name:
If a user defined name is administered for the DS1 circuit pack, it will 
be displayed here. Blank means no user defined name was given to 
this DS1 circuit pack.
Slip:
If the DS1 circuit pack has slip alarm, this field will show ’y’. Otherwise 
it will show ’n’.
Port Network:
This field is only valid for stratum 3 synchronization. The field is a 
display only field and specifies the port network that supplies 
synchronization via the tone clock circuit pack.
 
 change synchronization                      Page   1 of   1
              SYNCHRONIZATION PLAN
       SYNCHRONIZATION SOURCE (DS1 circuit pack location)
           Stratum: 4
           Primary: _____    Secondary: _____
 Location  Name    Slip        Location  Name    Slip
  NOTE: TN722B DS1 source will result in stratum 4, type II synchronization
 
 change synchronization                      Page   1 of   1
              SYNCHRONIZATION PLAN
       SYNCHRONIZATION SOURCE (DS1 circuit pack location)
             Stratum: 3
        Port Network: 1