DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-60
change system-parameters maintenance 
8
Operations Support Parameters
Product 
Identification
This is a 10-digit number starting with 1 that identifies the switch to an 
Operations Support System (OSS), for example, INADS.
First OSS 
Telephone 
Number
The first telephone number that the switch uses to report alarms to, for 
example, INADS or Trouble Tracker. The number must be obtained 
from the National Customer Support Center (NCSC) or the TSC. 
#
 and 
*
 
are not allowed in the telephone number.
Abbrev Alarm 
Report
Enables the Abbreviated Alarm Report feature for the first OSS. (yes)
Second OSS 
Telephone 
Number
The second telephone number that the switch uses to report alarms to, 
for example, INADS or DEFINITY SNMP. The number must be obtained 
from the National Customer Support Center (NCSC) or the TSC. 
#
 and 
*
 
are not allowed in the telephone number.
Abbrev Alarm 
Report
Enables the Abbreviated Alarm Report feature for the second OSS. (no)
Alarm 
Origination to 
OSS Numbers
Indicates one of four options for alarm origination (neither):
If this field is set to “both,” all Major and Minor alarms result in an 
automatic call to both OSS telephone numbers. Both OSS 
telephone numbers must be administered.
If this field is set to “first-only,” all Major and Minor alarms result in 
an automatic call to the first OSS number only. The switch does not 
call the second OSS telephone number even if the number is 
administered. The first OSS telephone number must be 
administered
If this field is set to “neither,” alarm origination does not take place. 
Warning alarms are not reported to either numbers.
If this field is set to “second-as-backup,” all Major and Minor alarms 
result in an automatic call to the first OSS telephone number. If 
calling the first OSS telephone number fails four attempts, the 
switch starts to call the second OSS telephone number as a 
backup until calling the first OSS telephone number becomes 
successful. Both OSS telephone numbers must be administered.
Before Release 5, the name of this field is “Alarm Origination 
Activated.” If Alarm Origination is deactivated, both Cleared Alarm 
Notification and Restart Notification are disabled, even though they 
may still be activated in the administration.
Cleared 
Alarm 
Notification
Enables the switch to originate a call to the OSS and send an alarm 
resolution message whenever all previously reported Major and Minor 
alarms are resolved. Alarm Origination must be activated in order for 
Cleared Alarm Notification to work. (no)
Restart 
Notification
Enables the switch to originate a call to the OSS and report any system 
restarts caused by problems with the switch. Activate Alarm Origination 
for Restart Notification to operate.