Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-465
status isdn-testcall
8
All maintenance resources busy; try again later
Output
Port
This field specifies the physical address
(cabinet/carrier/slot/circuit) of the ISDN-PRI B-channel.
(cabinet/carrier/slot/circuit) of the ISDN-PRI B-channel.
Bit Error Rate
The measured bit error count according to the comparison of
the sent and received bit pattern. The number is displayed in
scientific notation (one significant digit and an exponent).
the sent and received bit pattern. The number is displayed in
scientific notation (one significant digit and an exponent).
Number of Bits
The number of bits generated. The number is displayed in
scientific notation (one significant digit and an exponent).
scientific notation (one significant digit and an exponent).
Block error Rate
The measured block error count according to the comparison
of the sent and received bit pattern. The number is displayed in
scientific notation (one significant digit and an exponent).
of the sent and received bit pattern. The number is displayed in
scientific notation (one significant digit and an exponent).
Number of Blocks
The number of blocks generated. The number is displayed in
scientific notation (one significant digit and an exponent).
scientific notation (one significant digit and an exponent).
Start Time
The time the test call started (dd/hh:mm).