Maintenance Commands and Trouble-Clearing Aids 
Page 8-465
status isdn-testcall 
8
All maintenance resources busy; try again later
Output
Port
This field specifies the physical address 
(cabinet/carrier/slot/circuit) of the ISDN-PRI B-channel.
Bit Error Rate
The measured bit error count according to the comparison of 
the sent and received bit pattern. The number is displayed in 
scientific notation (one significant digit and an exponent).
Number of Bits
The number of bits generated. The number is displayed in 
scientific notation (one significant digit and an exponent).
Block error Rate
The measured block error count according to the comparison 
of the sent and received bit pattern. The number is displayed in 
scientific notation (one significant digit and an exponent).
Number of Blocks
The number of blocks generated. The number is displayed in 
scientific notation (one significant digit and an exponent).
Start Time
The time the test call started (dd/hh:mm).