Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-466
status isdn-testcall 
8
For the following output example, the command status idsn-testcall 80/1 was 
entered.
Feature Interactions
If the bit error rate or block error rate is greater than zero, the ISDN-PRI trunk 
"may" be in a troubled state. Based on the statistical information displayed on the 
terminal, it can be decided to take the ISDN trunk out of service. This is 
Duration Specified
The duration specified in minutes for how long the test call 
should run. Valid durations are 1-120 (minutes) or blank (to 
indicate the default amount of 10 seconds was used to run the 
test).
Duration of Test
The duration specified in minutes for how long the test call has 
been running. A blank indicates that the default amount of time 
was used to run the test.
Reason of Termination
The reason of termination indicates why the test call has 
terminated. Valid reasons of termination are "finished," 
"canceled," "overflow," "no bits," "transmission," "internal fail," 
"data corrupt," "call dropped," "call rejected," and "in progress." 
A termination reason of "finished" means the test finished in the 
specified time. A termination reason of "canceled" means the 
test call has been canceled with the "clear isdn-testcall" 
command. A reason of "overflow" denotes that the bits 
transmitted have overflowed buffer allocation. A reason of "no 
bits" means that no bits have been received because the 
ISDN-PRI test call circuit connection is bad. A reason of 
"transmission" means there has been a data transmission 
interruption, probably caused from a power hit. A termination 
reason of "call dropped" indicates that the call dropped due to 
abnormal termination, or it couldn’t cut-through to the other 
side. A termination reason of "call rejected" means the 
originating call was not set up properly. A termination reason of 
"internal fail" specifies that there is an internal error on the 
Maintenance/Test circuit pack. A reason of "in progress" means 
the test is still running and a reason of "data corrupt" is used for 
any other error condition.
 
 status isdn-testcall 80/1                  Page 1 of   1   SPE A
                            ISDN TESTCALL STATUS
          Bit   Number Block Number          Duration         Reason
          Error Of     Error Of     Start    Duration  Of     Of
 Port     Rate  Bits   Rate  Blocks Time     Specified Test   Termination
 1B1401   0EE0  4EE7   0EE0  6EE2   25/12:36 120       100    in progress