Page 8-538
test alarms
8
Help Messages
If the technician presses
HELP
after entering "test alarms" the following message
will be displayed:
Enter [’auto-page’], [’failures’], [’step’],
[’short’ or ’long’], [’repeat’ (1-100) or ’clear’]
Error Messages
If the command entered is in conflict with another currently executing command,
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
then a message will be displayed showing the login id of the conflicting user and
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires
the user to restart the command, then the following message will be displayed:
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
long
This will execute a more comprehensive and longer version of the
diagnostic tests. This may involve both destructive and nondestructive
tests.
diagnostic tests. This may involve both destructive and nondestructive
tests.
repeat number
The "number" specifies how many times each test in the sequence is to
be repeated. "Number" may be any integer between 1 and 100.
be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the
alarm is cleared or a single test in the sequence fails. The long clear
option forces a clear of all alarms if no errors are encountered during
testing. The short clear option only clears alarms pertinent to tests in
the short sequence.
alarm is cleared or a single test in the sequence fails. The long clear
option forces a clear of all alarms if no errors are encountered during
testing. The short clear option only clears alarms pertinent to tests in
the short sequence.
!
WARNING:
Executing a clear with short option, may not clear all alarms even
if all tests pass.
if all tests pass.
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it is
possible for firmware counters to be cleared even when a
problem exists. In some cases customer service might degrade
since calls may be routed over defective equipment.