DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-538
test alarms 
8
Help Messages
If the technician presses 
HELP
 after entering "test alarms" the following message 
will be displayed:
Enter [’auto-page’], [’failures’], [’step’],
[’short’ or ’long’], [’repeat’ (1-100) or ’clear’]
Error Messages
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
long
This will execute a more comprehensive and longer version of the 
diagnostic tests. This may involve both destructive and nondestructive 
tests.
repeat number
The "number" specifies how many times each test in the sequence is to 
be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm is cleared or a single test in the sequence fails. The long clear 
option forces a clear of all alarms if no errors are encountered during 
testing. The short clear option only clears alarms pertinent to tests in 
the short sequence.
!
WARNING:
 Executing a clear with short option, may not clear all alarms even 
if all tests pass.
!
WARNING:
Since the "clear long" options clear all counters if tests pass, it is 
possible for firmware counters to be cleared even when a 
problem exists. In some cases customer service might degrade 
since calls may be routed over defective equipment.