Справочник Пользователя для Lucent Technologies R5SI
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids
Page 8-539
test alarms
8
If all of the available maintenance resources are currently in use, then the
following message will be displayed:
following message will be displayed:
All maintenance resources busy; try again later
QUERY FORM INPUT
After entering the command "test alarms", the system technician will be
presented with an options form for alarm selection.
presented with an options form for alarm selection.
Alarm Types
The type of alarm to be tested is specified by placing a ’y’ or ’n’ in the
alarm type fields. The technician can choose a combination of active
alarms: major, minor, and/or warning.
alarm type fields. The technician can choose a combination of active
alarms: major, minor, and/or warning.
Interval
Test alarms for records for the last hour (h), last day (d), last week (w)
or all (a). The default is all.
or all (a). The default is all.
test alarms repeat 1
HARDWARE TEST ALARM QUERY
The following options control which alarms will be tested.
ALARM TYPES
Major? y_ Minor? y_ Warning? y_
Major? y_ Minor? y_ Warning? y_
REPORT PERIOD
Interval: m_ From: __/__/__:__ To: __/__/__:__
Interval: m_ From: __/__/__:__ To: __/__/__:__
EQUIPMENT TYPE ( Choose only one, if any, of the following )
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): __/__
Cabinet: __
Port Network: __
Board Number: ____
Port: ______
Category: ________
Extension: _____
Trunk ( group/member ): __/__