Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-560
test cdr-link 
8
For information on what a CDR link is and does, see the second paragraph in the 
"Description" section of the "status cdr-link" manual pages.
Defaults
The default for the command is short with the repeat of 1.
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test cdr-link" the following 
message will be displayed:
Enter ’primary’ or  ’secondary’
If the system technician presses 
HELP
 after entering "test cdr-link primary" or "test 
cdr-link secondary" the following message will be displayed:
Enter [’long’ or ’short’],
[’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
If the link is not administered, the following error message will be displayed:
link-id
A "Link-id" is either "primary" or "secondary".
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.
long
This will execute a more comprehensive and longer version of the 
diagnostic tests. This may involve both destructive and nondestructive 
tests.
repeat number
The "number" specifies how many times each test in the sequence is to 
be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing. The short clear option only clears alarms 
pertinent to tests in the short sequence.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.