Maintenance Commands and Trouble-Clearing Aids 
Page 8-562
test customer-alarm 
8
Feature Interactions
None.
test customer-alarm
This command allows the technician to test the leads for a customer-provided 
alarming device on the Processor and EPN maintenance circuit packs.
Synopsis
test customer-alarm location 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
test customer-alarm
test customer-alarm schedule
test customer-alarm 02 r 2
test customer-alarm 01b r 25
test customer-alarm 01b r 25 schedule
test customer-alarm 2a
test customer-alarm 2a sh
test customer-alarm 01b l schedule
test customer-alarm 3 c
Description
The test customer-alarm command performs hardware diagnostic tests on the 
leads of the Processor and EPN maintenance circuit packs. These are used for 
customer provided alarms by closing the appropriate relay for one minute. 
Failure is verified by the technician checking the customer alarm attached to the 
circuit pack that was specified.
Defaults
The default cabinet is cabinet 1. The default carrier is carrier "a" except for SPE 
duplex system PPNs. In this case the carrier has no default and either "a" or "b" 
must be entered. The default for the remaining parameter is a repeat of 1.