DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-574
test duplication-interface 
8
Parameters
Help Messages
If the system technician presses 
HELP
 after entering "test duplication-interface," 
the following message is displayed:
Enter [network(1);carrier(A-B) [’long’ or ’short’],
  [’repeat’ (1-100) or ’clear’], [’schedule’]
Error Messages
For any system, if a user entered parameter is not among those listed in the 
"Parameters" section, the following message is displayed:
Entry invalid
If an invalid port network is specified, the following message is displayed:
Invalid port-network specified
If an invalid carrier is specified, the following message is displayed:
Invalid carrier specified
If the standby is entering maintenance mode when this command is executed, 
then the following message is displayed:
location
The location designates the SPE location of the desired duplication 
interface circuit pack; either "1a", "1b" "a" or "b".
short
This will cause the command to execute a series of nondestructive 
diagnostic tests.
long
This will execute a more comprehensive and longer version of the 
diagnostic tests. The long version includes a destructive test for this 
command.
repeat number
The "number" specifies how many times each test in the sequence is 
to be repeated. "Number" may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until the 
alarm (if one exists against the maintenance object) is cleared or a 
single test in the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once. The long clear option forces a clear of all alarms if no errors are 
encountered during testing.
schedule
When the "schedule" option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed in 
the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specification [1] for more details.