Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-674
test tone-clock 
8
For the following output example, assume that the command that was entered 
was "test tdm port-network 1".
Feature Interactions
None.
test tone-clock
This command will test a tone/clock board.
Synopsis
test tone-clock location 
[ short | long ][ repeat number | clear ] schedule
Permissions
The following default logins may execute this command: system technician, 
inads, init.
Examples
test tone-clock 01a l 
test tone-clock 01b l schedule
Description
The test tone/clock command performs hardware diagnostic tests on a 
technician specified tone/clock circuit pack.
 
 test tdm port-network 1
                             TEST RESULTS
 
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
   PN 01A  TDM-BUS                     294      PASS
   PN 01A  TDM-BUS                     296      PASS
   PN 01A  TDM-BUS                     297      PASS
   PN 01B  TDM-BUS                     294      PASS
   PN 01B  TDM-BUS                     296      PASS
   PN 01B  TDM-BUS                     297      PASS
 Command Successfully Completed