Справочник Пользователя для Lucent Technologies R5SI

Скачать
Страница из 2643
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-677
test trunk 
8
For the following output example, assume that the command that was entered 
was "test tone-clock 1a".
Feature Interactions
None.
test trunk
This command will test an entire trunk group or a specific trunk group member.
Synopsis
test trunk group number
/member number [ short | long ][ repeat number | clear ] 
schedule
Permissions
The following default logins may execute this command: system technician, 
inads, cust, init.
Test No
The actual test that is being executed.
Result
The result of the individual test -"PASS," "ABORT," "FAIL," "NO 
BOARD," "DISABLED," "EXTRA BD."
Error Code
A system-generated number that tells why the release failed or 
aborted.  A detailed list of the codes according to "Test No." is 
provided for each MO.
 
 test tone-clock 1a
                            TEST RESULTS
 
   Port    Maintenance Name  Alt. Name Test No. Result       Error Code
   01A     TONE-BD                     46       PASS
   01A     TONE-BD                     52       PASS
   01A     TONE-PT                     40       PASS
   01A     TONE-PT                     41       PASS
   01A     TDM-CLK                     148      PASS
   01A     TDM-CLK                     149      PASS
   01A     TDM-CLK                     150      PASS
   01A     TDM-CLK                     151      PASS
   01A     TDM-CLK                     574      PASS
 Command Successfully Completed