DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Initialization and Recovery 
Page 4-8
Procedure for SPE-Down Mode 
4
Procedure for SPE-Down Mode
Due to fatal hardware and software problems, it is possible for a system to go 
into SPE-Down Mode. In this mode, the system invokes emergency transfer and 
does not provide any other service. Moreover, while in this mode, the software 
does not (or cannot) run at all. In a high or critical reliability system the system 
goes into SPE-Down mode 
only when both SPEs go into SPE-Down mode
.
There is an interface to the system by maintenance. The Processor circuit pack, 
is responsible for maintenance in a standard reliability system. In a high or 
critical reliability system, the maintenance is provided by the A-carrier 
Duplication Interface (DUPINT-A) TN772 circuit pack with help from the 
processor.
The administration terminal, which connects directly to the processor in a 
standard reliability system and to DUPINT-A in a high or critical reliability system, 
provides a very limited interface to the system. Technicians can display alarms or 
restart the system. Only a subset of control complex alarms displays.
The following are sample displays for SPE-Down mode and the alarms 
displayed.
Display for SPE-Down in a Standard Reliability system:
**************SPE DOWN MODE*************
You can display alarms and reset system(4).
SPE_DOWN->
 and 
 show all possible SPE-Down alarms in a standard 
reliability system and in a high or critical reliability system, respectively.
Screen 4-1.
Display Alarms Command 
 
 DISPLAY ALARMS:
      Physical   Logical   On       Alternate   Alarm       Date        Date
      Name       Name      Board?   Name        Type        Alarmed     Resolved
      ------     PROC_BD   y        -----       MAJOR       ------      ------
      ------     MEM_BD_0  y        -----       MAJOR       ------      ------
      ------     M_BUS     y        -----       MAJOR       ------      ------
      ------     MAINT*    y        -----       MAJOR       ------      ------
      ------     NETCON_BD y        -----       MAJOR       ------      ------
      ------     TAPE_UNIT ------   -----       MAJOR       ------      ------
      ------     NO_TAPE   ------   -----       MAJOR       ------      ------