DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-25
ADX8D-PT (AUDIX Digital Port) 
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times.
Voice and Control Channel Local Loop Test (#13)
This test checks the information and control channels between the Switch 
Processing Element (SPE) and the DEFINITY AUDIX port circuit. First, the 
primary information (voice) channel loop back test is run. 
1002
ABORT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions, or it may have time slots out-of-service due to 
TDM-BUS errors. Refer to “TDM-BUS” to diagnose any active TDM-BUS 
errors.
1. If system has no TDM-BUS errors, and if it is not handling heavy traffic, 
try (a).
1003
ABORT
The system could not allocate a tone receiver for the test. The system may be 
oversized for the number of Tone Detectors present, or some Tone Detectors 
may be out-of-service.
1. Resolve any “TTR-LEV” errors.
2. Resolve any “TONE-PT” errors. Try (a).
1004
ABORT
The port was put in use during the test. The test has been aborted. Use the 
display port PCSSpp
 command to determine the voice port extension of the 
port. Use the 
status station
 command to determine the service state of the 
port. If the port is in use, wait until the port is idle before testing.
1020
ABORT
Test disabled by background testing. Use the 
status station
 command to 
determine when the voice port is available for testing.
2000
ABORT
Response to the test request was not received within the allowable time 
period. Try (a).

FAIL
The NPE of the tested port is transmitting in error. This causes noisy and 
unreliable connections. Failure code 1 indicates that the Crosstalk test failed 
on the primary channel. Failure code 2 indicates that the Crosstalk test failed 
on the secondary channel.
1. Replace the circuit pack .
PASS
The port is using its allocated time slots correctly.
1. To be sure that this is not an intermittent problem, repeat this test up to a 
maximum of 10 times to make sure it continues to pass.
2. If complaints still exist, examine the connections.
Table 10-10.
TEST #9 NPE Crosstalk Test  — 
Continued
Error 
Code
Test 
Result
Description/Recommendation
Continued on next page