DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-29
ADX16A-BD (AUDIX Circuit Pack) 
10
ADX16A-BD (AUDIX Circuit Pack)
The ADX16A-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack combination operating in control-link (CL) mode. For 
circuit-pack-level problems, see “XXX-BD (Common Port Circuit Pack)”. 
Port-level maintenance is covered by ADX16A-PT.
DEFINITY AUDIX consists of 2 circuit packs that occupy 5 slots on a port carrier. 
The tests described in this manual apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy that is described in 
DEFINITY 
AUDIX System Maintenance
, 585-300-110.
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). 
SS is the number of the slot in which the circuit pack
resides (01 to 21).
MO Name (in 
Alarm Log)
Alarm Level
Initial Command To 
Run
1
Full Name of MO
ADXCL-BD or 
\ADX16A-BD
MINOR, or 
WARNINGS
test board PCSS sh
AUDIX Circuit Pack