DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-31
ADX16D-P (16-Port AUDIX Digital Port) 
10
Error Log Entries and Test to Clear Values
Notes:
a. The user may experience a noisy port or link. This is an off-board problem 
that is detected by the port circuit. If this problem exists, replace the 
circuit pack (see caution at the beginning of this section). Once the 
problem is resolved, the alarm is retired after a predetermined time.
b. At least 15 off-board problems have been detected with the link to the 
voice port. When an error with the link is detected, an on-board counter is 
incremented. Also see Note a, above.
c. This is an internal type error that occurs when an audit request fails.
d. The port is busied-out by command. Release the port with the 
release 
port PCSSpp
 command.
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate
test description and follow the recommended procedures.
2.
Minor alarms may be downgraded to Warning alarms based on the values used in the 
set options
command.
Table 10-12.
DEFINITY AUDIX Digital Port Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
0
Any
Any
Any
test port PCSSpp sh r 1
1(a)
40987
None
WARNING
OFF
1(b)
1 to 20
None
WARNING
OFF
15(c)
Any
None
18(d)
0
busyout port PCSSpp
WARNING
OFF
release port PCSSpp
23(e)
0
None
WARNING
OFF
130(f)
None
WARNING
ON
test port PCSSpp sh
257(g)
40971
None
513(h)
Any
None
1537(i)
40968
None
WARNING
OFF
1793
Voice and Control 
Local Loop TEST 
(#13)
MIN/ WRN
2
ON
test port PCSSpp l r 3
2049
NPE Crosstalk Test 
(#9)
MIN/ WRN
2
ON
test port PCSSpp l r 3
2305(j)
40967
None
3840(k)
40965
None
3840(l)
41029
None