DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si  
555-230-123  
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-32
ADX16D-P (16-Port AUDIX Digital Port) 
10
e. The circuit pack is administered but not physically installed. The alarm will 
clear when a circuit pack is inserted.
f. The circuit pack has been removed or has been insane for more than 21 
minutes. To clear the error, reseat or replace the AUDIX circuit pack (see 
caution at the beginning of this section).
g. Something is interfering with transmitting to the voice port. This is usually 
an on-board problem and can be ignored if no user complaints are 
received.
h. AUDIX is not available to the switch, possibly due to a busyout on the 
AUDIX system. Refer to 
DEFINITY AUDIX System Maintenance
585-300-110, if necessary.
i. An in-line maintenance error has generated an off-board warning due to 
some problem with the link to the voice port. This can be ignored if no user 
complaints are received. If the problem persists, replace the circuit pack 
(see caution at the beginning of this section). Once the problem is 
resolved, the alarm is retired after a certain period of time.
j. The link between the circuit pack and the voice port is successfully reset. 
No craft action is necessary.
k. No voice ports are connected to the DEFINITY AUDIX circuit pack. No 
maintenance action is required.
l. The message buffer in the circuit pack is full. 
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
Voice and Control Channel Local Loop Around 
Test
 for example, you may also clear errors generated from other tests in the 
testing sequence.
NO-OP Tests
The maintenance strategy for DEFINITY AUDIX emulates the one for DIG-LINE. 
The tests listed below apply only to DIG-LINE and not to DEFINITY AUDIX. These 
tests always return PASS.
1.
D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
Voice and Control Channel Local Loop Around Test (#13)
X
ND
NPE Crosstalk Test (#9)
X
ND