Листовка для Oregon Scientific PD09535M

Скачать
Страница из 2
3.
Press it again to turn off both of them until the
icons disappear.
Note:
1.
To turn on temperature pre-alarm, ALARM must
be on.
2.
The temperature pre-alarm can sound 30 minutes
earlier  than  the  alarm  only  when  the  outdoor
temperature is below -3°C (26°F).
3.
If no key is pressed during the alarm period, the
clock will enter the snooze mode automatically.
Besides,  you  can  also  press  “SNOOZE”  key
once to stop the current alarm and activate the
snooze  function.
4.
Once  the  snooze  function  is  activated,  the  4-
step crescendo alarm will sound 13 times in 5-
minute  interval.  The  alarm  duration  is  60
seconds.
VIEWING  THE  CHANNEL
The default channel is Channel 1. Press “CHANNEL”
key to view the channels from 1 to 3.
Besides, press and hold “CHANNEL” key for 2 seconds
to show the channels automatically; press it once again
to exit the automatic display mode.
HOW  TO  READ  TEMPERATURE  RECORDS
Change the temperature unit to °C for Celsius or °F for
Fahrenheit  by  pressing  “°C/°F”  key.
Note:
1.
If no signals are received or the transmission is
interfered, “---” will appear on the LCD.
2.
Relocate  the  clock  or  transmitter  in  other
positions  and  make  sure  the  transmission  is
within the effective range of 30 meters approx.
3.
After  several  trials  in  vain,  please  reset  the
clock  thoroughly.  Try  out  where  your
multifunctional alarm clock receives the signals
best.
CHECKING    AND    DELETING    MAX./MIN.
TEMPERATURE RECORDS
1.
Press  “MAX/MIN”  key  once  to  check  the
maximum temperature records. Press it twice to
check  the  minimum  records.  Press  it  again  to
exit.
2.
Press and hold “MAX/MIN” key for 3 seconds to
delete the max. and min. temperature records.
    WEATHER  FORECAST  INDICATOR
The built-in barometer can notice atmosphere pressure
changes. Based on the data collected, it can predict
the weather conditions in the forthcoming 12-24 hours.
Note:
1.
The  accuracy  of  a  general  pressure-based
weather forecast is about 70% to 75%.
2.
The weather forecast is meant for next 12 to 24
hours. It may not necessarily reflect the current
situation.
3.
The  “Rainy”  and  “Stormy”  icons  are  different
only in the dropping frequency of the rain. The
rain dropping frequency in “Stormy” icon is faster
than that in “Rainy” icon.
4.
The “Snowy” weather forecast is not based on
the  atmosphere  pressure  but  on  the  outdoor
temperature. When the outdoor temperature is
below  -3°C  (26°F),  the  “Snowy”  icon  will  be
displayed on the LCD.
    ABOUT  THE  MOON  PHASE
The unit has 8 different moon phases. It will change
according to the lunar calendar.
  BATTERY  REPLACEMENT
If  the  LCD  becomes  dim,  it  means  that  you  should
replace batteries of the clock immediately.
If  the  low  battery  indicator  “
”  appears  in  the
WEATHER FORECAST AND TEMPERATURE window
of the clock (“
  ”) or on the LCD of transmitter, you
should replace batteries of transmitter at once.
Note:
Attention! Please dispose of used unit or batteries in
an ecologically safe manner.
USING  THE  TABLE  STAND  OR
   WALL-MOUNTING  STAND
The receiver and transmitter have both the desktop
and wall-mounting structures.
For the receiver, place the screw on the desired wall
and  hang  the  receiver  by  the  recessed  hole  in  the
back of it or just simply place it on the desktop by its
table stand.
For  the  transmitter,  fix  the  separate  wall-mounting
stand outside in the area protected from direct rain by
the  screw.  Once  the  stand  is  mounted,  place  the
transmitter  into  the  stand  on  the  wall.  Besides,  you
can also place it on the desktop by its table stand.
  SPECIFICATIONS
 Note  We recommend that you use alkaline batteries
with this product for longer usage and lithium batteries
in temperatures below freezing.
PRECAUTIONS
Do  not  subject  the  unit  to  excessive  force,
shock,  dust,  temperature  or  humidity.
Do not cover the ventilation holes with any items
such as newspapers, curtains etc.
Do  not  immerse  the  unit  in  water.  If  you  spill
liquid over it, dry it immediately with a soft, lint-
free  cloth.
Do not clean the unit with abrasive or corrosive
materials.
Do not tamper with the unit’s internal components.
This invalidates the warranty.
Only use fresh batteries. Do not mix new and old
batteries.
Images  shown  in  this  manual  may  differ  from
the  actual  display.
When  disposing  of  this  product,  ensure  it  is
collected  separately  for  special  treatment  and
not as normal household waste.
Placement  of  this  product  on  certain  types  of
wood may result in damage to its finish for which
Oregon Scientific will not be responsible. Consult
the furniture manufacturer’s care instructions for
information.
The contents of this manual may not be reproduced
without the permission of the manufacturer.
Do not dispose old batteries as unsorted municipal
waste.  Collection  of  such  waste  separately  for
special  treatment  is  necessary.
Please note that some units are equipped with a
battery  safety  strip.  Remove  the  strip  from  the
battery  compartment  before  first  use.
  Note The  technical  specifications  for  this  product
and  the  contents  of  the  user  manual  are  subject  to
change without notice.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn
more about Oregon Scientific products. If you’re in the
US  and  would  like  to  contact  our  Customer  Care
department  directly,  please  visit:
www2.oregonscientific.com/service/support
OR
Call 1-800-853-8883.
MAX. Temperature records
MIN. Temperature records
Sunny
Slightly cloudy
Cloudy
Rainy
Stormy
Snowy
Waxing crescent 
New moon 
First quarter Waxing gibbous
Full moon Waning gibbous Last quarter Waning crescent
Transmitter’s low battery indicator
(shows on the transmitter)
Transmitter’s low battery indicator
(shows on the main unit)
DOWN
UP
C /  F
SYNC
O
O
DESCRIPTION
430 (W) x 33 (D) x
 (H) mm
288
(16.93 x 1.3 x 11.34 in)
433 MHz
0 °C to 45 °C 32 °F to 113 °F
  (
)
from year 2000 to 2099
4 x AA  1.5V  batteries
40 (W) x
 (D) x
 (H) mm
23.5
128
(1.57 x0.93 x
 in)
5.04
433 MHz
3
TYPE
MAIN UNIT
L x W x H
Signal frequency
Temperature
range
Moon  phase
scanner range:
Power
REMOTE UNIT 
L x W x H
Signal frequency
Number of channel
Transmission range 30 m (98 ft) unobstructed
Weight
Weight
-20 °C to 55 °C 
-4 °F to 131 °F
2 x AA  1.5V  batteries
Temperature range
Power
EU-DECLARATION OF CONFORMITY
Hereby, Oregon Scientific, declares that the Indoor /
Outdoor Thermometer   (Model JW102 ) is in compli-
ance  with  the  essential  requirements  and  other  rel-
evant  provisions  of  Directive  1999/5/EC.
A  copy  of  the  signed  and  dated  Declaration  of
Conformity is available on request via our Oregon
Scientific  Customer  Service.
COUNTRIES RTTE APPROVAL COMPLIED
ALL EU countries, Switzerland
CH
                                           and Norway
N