MELSEC-Q
 
11   TROUBLESHOOTING 
 
Special Relay List 
(2) System information 
 
Number
 
Name
 
Meaning
 
Explanation
 
Set by 
(When Set)
 
Corresponding 
ACPU 
M9 
 
 
 
Applicable 
CPU 
SM202 
LED OFF 
command 
OFF 
ON : LED OFF 
• When this relay goes from OFF to ON, the LEDs 
corresponding to the individual bits at SD202 go off 
U New 
SM203  STOP contact 
STOP status 
• Goes ON at STOP status 
S (Status 
change) 
M9042 
SM204  PAUSE contact 
PAUSE status 
• Goes ON at PAUSE status 
S (Status 
change) 
M9041 
SM205 
STEP-RUN 
contact 
STEP-RUN status 
• Goes ON at STEP-RUN status 
S (Status 
change) 
M9054 
PAUSE enable 
coil 
OFF : PAUSE disabled 
ON  : PAUSE enabled 
• PAUSE status is entered if this relay is ON when the 
remote PAUSE contact goes ON 
U M9040 
 
SM206 
Device test 
request 
acceptance 
status 
OFF : Device test not yet  
 
  executed 
ON  : Device test executed 
• Comes ON when the device test mode is executed on 
GX Developer. 
S (Request) 
New 
Remote 
SM210 
Clock data set 
request 
OFF :  Ignored 
ON  : Set request 
• When this relay goes from OFF to ON, clock data being 
stored from SD210 to SD213 after execution of END 
instruction for changed scan is written to the clock device. 
U M9025 
SM211  Clock data error 
OFF : No error 
ON : Error 
• ON when error is generated in clock data (SD210 to 
SD213) value, and OFF if no error is detected. 
S (Request) 
M9026 
 
SM212 
Clock data 
display 
OFF :  Ignored 
ON : Display 
• Displays clock data as month, day, hour, minute, and 
second at the LED display at front of CPU module. 
U M9027 
Q3A 
Q4A 
Q4AR 
SM213 
Clock data read 
request 
OFF :  Ignored 
ON  : Read request 
• When this relay is ON, clock data is read to SD210 to 
SD213 as BCD values. 
U M9028 
+Rem 
SM240 
No. 1 CPU reset 
flag 
OFF : PLC No. 1 reset cancel 
ON  : PLC No. 1 resetting 
• Goes OFF when reset of the PLC No. 1 is canceled. 
• Comes ON when the PLC No. 1 is resetting (including 
the case where the PLC is removed from the base unit). 
The other PLCs are also put in reset status. 
SM241 
No. 2 CPU reset 
flag 
OFF : PLC No. 2 reset cancel 
ON  : PLC No. 2 resetting 
• Goes OFF when reset of the PLC No. 2 is canceled. 
• Comes ON when the PLC No. 2 is resetting (including 
the case where the PLC is removed from the base unit). 
The other PLCs result in "MULTI CPU DOWN" (error 
code: 7000). 
SM242 
No. 3 CPU reset 
flag 
OFF : PLC No. 3 reset cancel 
ON  : PLC No. 3 resetting 
• Goes OFF when reset of the PLC No. 3 is canceled. 
• Comes ON when the PLC No. 3 is resetting (including 
the case where the PLC is removed from the base unit). 
The other PLCs result in "MULTI CPU DOWN" (error 
code: 7000). 
SM243 
No. 4 CPU reset 
flag 
OFF : PLC No. 4 reset cancel 
ON  : PLC No. 4 resetting 
• Goes OFF when reset of the PLC No. 4 is canceled. 
• Comes ON when the PLC No. 4 is resetting (including 
the case where the PLC is removed from the base unit). 
The other PLCs result in "MULTI CPU DOWN" (error 
code: 7000). 
SM244 
No. 1 CPU error 
flag 
OFF : PLC No. 1 normal 
ON  : PLC No. 1 during stop  
 
  error 
• Goes OFF when the PLC No. 1 is normal (including a 
continuation error). 
• Comes ON when the PLC No. 1 is during a stop error. 
SM245 
No. 2 CPU error 
flag 
OFF : PLC No. 2 normal 
ON  : PLC No. 2 during stop  
 
  error 
• Goes OFF when the PLC No. 2 is normal (including a 
continuation error). 
• Comes ON when the PLC No. 2 is during a stop error. 
SM246 
No. 3 CPU error 
flag 
OFF : PLC No. 3 normal 
ON  : PLC No. 3 during stop 
 
  error 
• Goes OFF when the PLC No. 3 is normal (including a 
continuation error). 
• Comes ON when the PLC No. 3 is during a stop error. 
SM247 
No. 4 CPU error 
flag 
OFF : PLC No. 4 normal 
ON  : PLC No. 4 during stop  
 
  error 
• Goes OFF when the PLC No. 4 is normal (including a 
continuation error). 
• Comes ON when the PLC No. 4 is during a stop error. 
S (Status 
change) 
New 
QCPU 
function 
Ver. B