Справочник Пользователя для Barco 26-0503000-00

Скачать
Страница из 108
MatrixPRO  •  8x8 DVI Router  •  User’s Guide
81
6.  Upgrading Software
Serial Upgrade Method
e.  If the prompt appears, continue with step 10 (uploading files).
9.  To troubleshoot the serial connection:
a.  If the DCD and CTS status lights are green, re-check the communication 
settings in the loader, and verify that the COM port and Baud Rate 
settings are correct.
b.  To verify MatrixPRO communication settings, using the MatrixPRO 
menu, select SETUP to display the Setup Menu.
c.  From the System Menu, select 
RS-232 Settings
 to display the RS-
232 Settings Menu.  
Figure 6-2.  MatrixPRO RS-232 Settings Menu
d.  Ensure that the baud rate is set to 115200.  Other parameters cannot be 
changed.  
e.  Repeat steps 7 and 8 above, then re-check the status lights.  
f. 
With communication status OK, continue with step 10.
10.  To upload files to MatrixPRO, click "Open script file to read and upload."
11.  In the dialog, select "Complete_Load.sld" and click Open.  The MatrixPRO menu 
should immediately display the "System in LOADER MODE" message.
12.  It takes several minutes to load the flash memory.  When complete, the Flash 
Loader utility displays the “Upload Complete” message.  Click OK to continue.
13.  Cycle power on the MatrixPRO, and exit the Flash Loader utility.
14.  On MatrixPRO, perform a factory reset.  In Chapter 4, refer to the 
” section on page 39 for instructions.    
15.  On MatrixPRO, verify that the new software has been loaded correctly.  In 
Chapter 4, refer to the “
” section on page 39 for instructions.
This completes the software upgrade procedure via serial communications.
R S - 2 3 2   S E T T I N G S
> B a u d   R a t e
1 1 5 2 0 0
P a r a m e t e r s
[ N 8 1 ]