Справочник Пользователя для Panduit DPOE12U1XY
PANDUIT
® DPoE™ Power Patch Panel User’s Guide
Issue 2.2
Part Number: PN378A
57
Table 17: Color-Coded Wire Positions for 802.3af-2003 Compliant Devices
Pin
Outs
Outs
EIA/TIA 568A
Pin
Outs
Outs
EIA/TIA 568B
5 WHITE/BLUE
5 WHITE/BLUE
4 BLUE
4 BLUE
1 WHITE/GREEN
1 WHITE/ORANGE
2 GREEN
2 ORANGE
3 WHITE/ORANGE
3 WHITE/GREEN
6 ORANGE
6 GREEN
7 WHITE/BROWN
7 WHITE/BROWN
8 BROWN
8 BROWN
The DPoE™ Power Patch panel supports standard IEEE 802.3af-2003 devices as well as alternate PoE
devices consistent with the Cisco legacy devices.
devices consistent with the Cisco legacy devices.
Table 18: Color-Coded Wire Positions for Alternate PoE Devices
Pin
Outs
Outs
EIA/TIA 568A
Pin
Outs
Outs
EIA/TIA 568B
5 WHITE/BROWN
5 WHITE/BROWN
4 BROWN
4 BROWN
1 WHITE/GREEN
1 WHITE/ORANGE
2 GREEN
2 ORANGE
3 WHITE/ORANGE
3 WHITE/GREEN
6 ORANGE
6 GREEN
7 WHITE/BLUE
7 WHITE/BLUE
8 BLUE
8 BLUE
7. For best performance, the cable pair twists should be maintained as close as possible to the point
of termination. Punchdown the conductors with a 110 Punchdown tool (PANDUIT part
no.PDT110). Record port information on the PANDUIT DPoE™ Power Patch Panel Installation
Worksheet (PANDUIT part no. PN377*). To ensure proper shielding, there must be approximately
1" (25.4 mm) between the cable foil or braid covered with copper tape and the punchdown
connector.
no.PDT110). Record port information on the PANDUIT DPoE™ Power Patch Panel Installation
Worksheet (PANDUIT part no. PN377*). To ensure proper shielding, there must be approximately
1" (25.4 mm) between the cable foil or braid covered with copper tape and the punchdown
connector.
NOTE:
The DPoE™ Power Patch Panel can
terminate most 22-24 AWG solid or
stranded IWC wire with a .050”
(1.27mm) max o.d. either PVC or
Plenum rated.
terminate most 22-24 AWG solid or
stranded IWC wire with a .050”
(1.27mm) max o.d. either PVC or
Plenum rated.