Chapter 3
Hardware Overview
© National Instruments Corporation
3-9
clock; this feature must be explicitly enabled in software. The TCXO 
output also can be routed out to the CLKOUT connector.
In addition to replacing the native backplane clock directly, the TCXO can 
phase lock to an external frequency source. This operation is discussed in 
detail in the 
 section.
Routing Signals
The NI PXIe-6672 has versatile trigger routing capabilities. It can 
route signals to and from the front panel, the PXI triggers, and the PXI star 
triggers.
The CLKIN SMB input on the NI PXIe-6672 may be used for PXI_CLK10 
replacement by either routing a 10 MHz signal directly from the CLKIN 
input to PXI_CLK10_IN, or by using the CLKIN input as a phase lock 
reference for the TCXO. When phase locking the TCXO to CLKIN, 
CLKIN may be any multiple of 1 MHz to 105 MHz. In addition, CLKIN is 
a valid source for PXI_Star.
The CLKOUT SMB on the NI PXIe-6672 may also be used to route the 
TCXO, PXI_CLK10, or DDS Clock.