Chapter 3
Hardware Overview
3-12
ni.com
Table 3-4 summarizes the sources and destinations of the NI PXIe-6672. 
The destinations are listed in the horizontal heading row, and the sources 
are listed in the column at the far left. A 
✓ in a cell indicates that the source 
and destination combination defined by that cell is a valid routing 
combination.
Using Front Panel PFIs As Inputs
The front-panel PFIs can receive external signals from 0 to +5 V. They can 
be terminated programmatically with 50
Ω resistances to match the cable 
impedance and minimize reflections.
Note
Terminating the signals with a 50
Ω resistance is recommended when the source is 
another NI PXIe-6672 or any other source with a 50
Ω output.
The voltage thresholds for the front-panel PFI inputs are programmable. 
The input signal is generated by comparing the input voltage on the 
Table 3-4.  Sources and Destinations for NI PXIe-6672 Signal Routing Operations
Sour
ce
s
Destinations
Front Panel
Backplane
Onboard
Fr
o
n
t P
a
ne
l
CLKOUT
PFI <0..5>
PXI_ 
CLK10_IN
PXI_Star 
Trigger 
<0..16>
PXI TRIG 
<0..7>
TCXO 
Reference
PLL
CLKIN
*
*
*
PFI <0..5>
Backplane
PXI_ CLK10
PXI_STAR 
<0..16>
PXI TRIG 
<0..7>
On
boa
rd
TCXO
*
*
*
DDS
Global 
Software 
Trigger
Can be accomplished in two stages by routing source to PXI_CLK10_IN, replacing PXI_CLK10 with PXI_CLK10_IN 
(occurs automatically in most chassis), and then routing PXI_CLK10 to the destination. The source must be 10 MHz.
† 
Routing PXI_CLK10 or DDS to PFI, PXI_Star, or PXI_Trigger is accomplished by setting PXI_CLK10 or DDS to be the 
synchronization clock (NI-Sync Property Node) and then routing the synchronization clock as the source.