Chapter 2
Installation and Configuration
© National Instruments Corporation
2-15
Complete the following steps to reserve these trigger lines in MAX.
1.
In the Configuration tree, click on the PXI chassis branch you want to 
configure.
2.
Then, in the right-hand pane, toward the bottom, click on the 
Triggers tab.
3.
Select which trigger lines you would like to statically reserve.
4.
Click the Apply button.
PXI Trigger Bus Routing
Some National Instruments chassis, such as the PXI-1065 and the 
PXI-1044/1045, have the capability to route triggers from one bus to others 
within the same chassis using the Trigger Routing tab in MAX, as shown 
in Figure 2-6.
Note
Selecting any non-disabled routing automatically reserves the line in all trigger 
buses being routed to. If you are using NI-DAQmx, it will reserve and route trigger lines 
for you, so you won’t have to route trigger lines manually.
Complete the following steps to configure trigger routings in MAX.
1.
In the Configuration tree, select the chassis in which you want to 
route trigger lines.
2.
In the right-hand pane, select the Trigger Routing tab near the bottom.
3.
For each trigger line, select Route RightRoute Outward From 
Middle
, or Route Left to route triggers on that line in the described 
direction, or select Disabled for the default behavior with no manual 
routing.
4.
Click the Apply button.