Chapter 3
Maintenance
3-2
ni.com
Exterior Cleaning
Clean the exterior surfaces of the chassis with a dry lint-free cloth or a 
soft-bristle brush. If any dirt remains, wipe with a cloth moistened in a mild 
soap solution. Remove any soap residue by wiping with a cloth moistened 
with clear water. Do not use abrasive compounds on any part of the chassis.
Caution
Avoid getting moisture inside the chassis during exterior cleaning, especially 
through the top vents. Use just enough moisture to dampen the cloth.
Do not wash the front- or rear-panel connectors or switches. Cover these components while 
cleaning the chassis.
Do not use harsh chemical cleaning agents; they may damage the chassis. Avoid chemicals 
that contain benzene, toluene, xylene, acetone, or similar solvents.
Resetting the AC Mains Circuit Breaker
If the NI PXIe-1065 chassis is connected to an AC source and encounters 
an over-current condition, the circuit breaker on the rear panel will trip to 
prevent damage to the chassis. Complete the following steps to reset the 
circuit breaker.
1.
Turn off the chassis.
2.
Disconnect the AC power cable.
3.
Depress the circuit breaker to reset it.
4.
Reconnect the AC power cable.
5.
Turn on the chassis.
If the circuit breaker trips again, complete the following steps:
1.
Turn off the chassis.
2.
Disconnect the AC power cable.
3.
Remove all modules from the chassis.
4.
Complete the procedure described in the 
section of Chapter 2, 
. If the power 
switch LED is not a steady green, contact National Instruments.
5.
Verify that the NI PXIe-1065 chassis can meet the power requirements 
of your CompactPCI or PXI Express modules. Overloading the chassis 
can cause the breaker to trip. Refer to Appendix A,