TX 4000 PCI SS7 Network Interface Board Installation Manual  
Configuring the TX 4000 board 
Moving a board 
Complete the following steps to move a TX board from one slot to another slot: 
Step 
Action 
Power down the system if it is running.  
Move the TX 4000 board from one slot to another slot, seating it firmly in the new slot. 
Power up the system. 
In a Windows system, if you are installing a TX 4000 board in a slot that has never held a TX 
4000 board, the Windows® New Hardware Wizard appears, finds the required files, and exits. 
At the prompt, invoke txcpcfg by entering the following command: 
txcpcfg 
txcpcfg displays the bus number, slot number, CP number, and CP model of boards that are 
present and configured. Only the bus number, slot number, and CP model type identify the 
board that you are currently configuring. The CP number is undefined. For example: 
Bus    Slot    CP Number    CP Model 
2      2       1            TX 4000 
2      4       2            TX 4000 
2      8       UNDEFINED    TX 4000 
Record the bus and slot values for the TX 4000 board that you moved. 
Assign a unique CP number to the undefined board by entering the following command: 
txcpcfg   bus   slot   unique_CP_number 
where 
• 
bus is the bus number of the TX 4000 board that you are configuring. 
• 
slot is the slot number of the TX 4000 board that you are configuring. 
• 
unique_CP_number is a number you assign. Valid CP numbers within the system start at 
1 and must be unique. They do not have to be consecutive. 
 
For example, enter the following command to assign a CP number of 3 for the board with a bus 
number of 2 and a slot number of 8: 
txcpcfg  2  8  3 
Verify the configuration change by entering the following command: 
txcpcfg 
txcpcfg displays configuration information. The following example indicates a CP number of 3 for 
the TX board with a bus number of 2 and a slot number of 8: 
Bus    Slot    CP Number    CP Model 
2      2       1            TX 4000 
2      4       2            TX 4000 
2      8       3            TX xxxx 
where xxxx is 4000 for a TX 4000, TX 4000/20, TX 4000C, or TX 4000/20C board. 
Save the configuration changes. 
In a Windows system, configuration changes are saved automatically. In a UNIX system, 
configuration changes are deleted when you restart the system. Save the changes by editing the 
cpcfg file as described in Saving configuration changes on page 27. 
Dialogic   Corporation 
 
 
 
 
 
 
 
 
25