Attach Z-CIM to Computer to be Added: 
For UKVMSPD Z-CIM: 
1.  Connect the 6-pin mini-DIN keyboard and mouse and HD15 video connectors on the UKVMSPD Z-
CIM to computer’s keyboard, mouse, and video ports. 
For UKVMSC Z-CIM with local port: 
1.  Connect CCPnn cable’s 6-pin mini-DIN and HD15 connectors to computer’s keyboard, mouse, and 
video ports. 
2.  Connect DB25 male end of CCPnn cable to DB25 female port on back of Z-CIM (UKVMSC).  
 
Attach new Z-CIM to the existing Z-CIM chain: 
1.  Remove Z-CIM Terminator from the last Z-CIM’s UTP IN port and set aside. 
2.  Connect a Category 5e UTP cable to UTP IN port on the Z-CIM that is currently last in the chain. 
3.  Connect the other end of this Category 5e UTP cable to the UTP OUT port on the next Z-
CIM/computer currently being added to the chain. 
4.  Place the Z-CIM Terminator in the added Z-CIM’s UTP IN port. 
5. Power 
ON 
computer. 
6.  Optional: Connect a local user console to the UKVMSC Z-CIM. 
 
Name Computer: 
1.  At the Selection Menu, press [F5] to go to the Administration Menu. 
2.  Select the Channel Configuration submenu. 
3.  Select the Z4200U device channel. 
4. Press 
[G] to bring up a Channel Configuration menu for the Z-CIM chain. 
5.  Use the [ ] and [ ] keys to highlight the Name field of the computer just connected via Z-CIM. The 
channel for this computer is displayed in green, and the highlight will turn yellow when it is selected. 
6. Press 
[Enter] - the highlight will turn blue. 
7.  Type the desired computer name - the highlight will turn green as you begin to type.  
8. Press 
[Enter] - the highlight will turn yellow. 
9. Press 
[S] to save the new name. 
 
Verify and Save Changes: 
1. Press 
[F2] to return to the Selection Menu. 
2.  The Selection Menu will display with the new computer name highlighted in white. 
3. Press 
[Enter] to switch to this selected computer. 
4.  Normal computer access and operation indicates a successful connection. 
Important: At least half of all machines in the Z-CIM chain must be powered ON at any given time 
in order for the Z-CIM chain to function properly. There must be enough power to support all of the 
Z-CIMs in the chain.