Chapter 4  Troubleshooting and Diagnostics 
IPmux-1/1E Installation and Operation Manual 
4-2  Error Detection
 
 
Table 4-1.  Event Types 
Event Description Corrective 
Action 
COLD_START 
The IPmux-1/1E has been powered up 
None 
PWR_ACTIVE 
IPmux-1/1E power supply unit is 
powered on 
None 
FATAL ERR 
IPmux-1/1E has encountered an 
internal fatal error 
The IPmux-1 requires servicing 
SYS USER RESET 
IPmux-1/1E was reset by the user 
None 
LOS START 
IPmux-1 has a LOS (loss of signal) state 
on its E1/T1 port 
1. 
Check the port cable connection 
2. 
Check input signal 
LOS END 
The LOS state detected has ended 
 
LOF START 
IPmux-1 has a LOF (Loss of frame 
synchronization) state on its E1/T1 port 
1. 
Check port cable connection 
2. 
Check input signal 
LOF END 
The LOF state detected has ended 
None 
LINE AIS START 
IPmux-1 has AIS (alarm indicator signal) 
state on its E1/T1 port 
Check for a fault at the PDH network, on the 
receive direction 
LINE AIS END 
The line AIS state detected has ended 
None 
LINE RDI START 
IPmux-1 has LINE RDI (remote defect 
indicator) state on its E1/T1 port 
Check for a fault at the E1/T1 connectivity 
on the transmit direction 
LINE RDI END 
The LINE RDI state detected has ended  None 
LINE FEBE START 
IPmux-1 has LINE FEBE state on its 
E1/T1 port 
Check for errors in the E1/T1 connection on 
the transmit direction 
LINE FEBE END 
The LINE FEBE state detected has 
ended 
None 
REMOTE FAIL START 
Ethernet frames are not received by the 
remote IPmux-1 on the specified 
connection 
Check Eth/IP path 
REMOTE FAIL END 
Remote fail state has ended 
None 
LOCAL FAIL START 
Ethernet frames are not received by the 
local IPmux-1 on the specified 
connection 
Check Eth/IP path 
LOCAL FAIL END 
Local fail state has ended 
None 