Chapter 4  Troubleshooting and Diagnostics 
 
Diagnostic Tests 
4-3 
4.2 Troubleshooting 
Table 4-2 presents the event types as they appear on the Event Log File and lists 
the actions required to correct the event (alarm) indication.  
Table 4-2.  IPmux-1 Troubleshooting Chart 
Fault 
Probable Cause 
Remedial Action 
E1/T1 equipment connected to 
IPmux-1 is not synchronized 
with IPmux-1/1E. 
Configuration problems 
 
Physical layer problems 
1. 
Check cables and physical connectivity. 
2. 
Check IPmux-1 E1/T1 configuration and, 
if necessary, other IPmux-1 parameters. 
3. 
Check E1/T1 physical connection (use 
loopbacks). 
Slips and errors in E1/T1/BRI/FXS 
equipment 
•  Ethernet port in switch and 
IPmux-1 are not in the same rate or 
duplex mode 
•  Ethernet port is set to work in half 
duplex mode (may cause extreme 
PDV because of collisions and 
backoffs) 
•  Timing configuration is not properly 
set (periodic buffer under/overflows 
shown on IP channel status menu) 
•  Deactivation employed by NT 
when IPmux is TE and in loopback 
timing mode 
•  Network PDV or lost frames 
1. 
Check E1/T1 physical connection (use 
loopbacks). 
2. 
Check timing settings according to 
explanation in this manual. 
3. 
Check switch and IPmux-1 port 
configuration (negotiation, rate, duplex 
mode) 
4. 
Check PDV introduced by the network, 
and, if necessary, increase PDVT jitter 
buffer setting. 
5. 
Check NT deactivation (BRI). 
Echo in voice 
High delay in voice path 
1. 
Check network delay and try to 
decrease it. 
2. 
Try to decrease PDVT (jitter) buffer.
 
4.3 Diagnostic Tests 
Maintenance capabilities include external and internal loopbacks. 
E1/T1 
External Loop 
IPmux-1 can be set to an external loop to test the connection between the E1/T1 
port and the PBX (refer to Chapter 3). In this mode, data coming from the PBX is 
both looped back to the PBX and transmitted forward to the IP network (see 
Figure 4-1).  
This mode can also be achieved by a T1 FDL line loopback command. 