Chapter 5  Application Configuration Procedures 
IPmux-1/1E Installation and Operation Manual 
5-10 IPmux-4
 
 
4. Select Next Hop and enter the next hop router IP address (this parameter is 
only necessary if the Destination IP Address is not in the same subnet as this 
IPmux. In such cases the Ethernet frame will be sent to the next hop IP 
address). 
5. Select Destination Bundle and enter 33 (which is the destination bundle on 
IPmux-4). 
6. Press <Esc> to return to the Bundle Connection Configuration screen. 
7. Press <Esc> to return to the Main screen. 
 
 
Remember to press <Enter> after modifying each parameter. Press <S> to save 
all changes on the menu. 
 
5.3 IPmux-4 
Powering-up 
➤ 
To turn on IPmux-4: 
1.  Make sure all IPmux-4 cables and connectors are properly connected. 
2.  Connect IPmux-4 to a PC equipped with an ASCII terminal-emulation 
application (for example, Windows 95 Hyper Terminal or Procomm). 
3.  Turn on the control-terminal PC and set its default port parameters to  
19,200 baud, 8 bits/character, No Parity, 1 stop bit.
  
4.  Set the terminal emulator to ANSI VT100 emulation (for optimal view of 
system menus).  
5.  Switch ON the POWER supply switch, located on the rear panel. 
6.  When the initialization and self-test are over, a menu appears displaying 
initialization and self-test results. If the self-test is successful, the RDY LED on 
the left side of the front panel lights up.  
➤ 
To logon: 
1. Press <Esc> to open the configuration software. 
2.  Enter your User Name as Supervisor (su) and press <Enter>. 
3.  Enter your Password (the factory-set password is xxxxxxxxxx).  
 
 
If you enter an invalid password in three consecutive attempts the system becomes 
inaccessible for 15 minutes. 
 
 
Note 
Note 