ASMi-31 Installation and Operation Manual 
Chapter 2.  Installation and Setup
16-05-01 13:37
Installation and Setup
2-5
Table 2-1  ASMi-31 Internal Jumpers and Switches (Cont.)
Item Jumper
Description
Values
Default Setting
3
LLB, JP15
Controls the local loopback
activation from the DTE
DIS
 – The LLB activation from
the DTE is disabled
EN
 – The LLB activation from
the DTE is enabled
DIS
4
CLOCK
Controls the ASMi-31 timing
reference
LBT
 – Loopback timing, clock is
recovered from the data at the
line side
INT
 – Internal clock
EXT
 – External clock
LBT
5
SW7
Selects the data rate
1
 – 1.2 kbps, sync/async
2
 – 2.4 kbps, sync/async
3
 – 4.8 kbps, sync/async
4
 – 9.6 kbps, sync/async
5
 – 19.2 kbps, sync/async
6
 – 38.4 kbps, sync/async
7
 – 48 kbps, sync
9
 – 64 kbps, sync
A
 – 128 kbps, sync
E
 – 16 kbps, sync
F
 – 32 kbps, sync
9 – 64 kbps
5
SW6
DIP switch, which consists of eight section
Section 1
Controls the ASMi-31 operation
mode – synchronous or
asynchronous
ON
 – Async operation
OFF
 – Sync operation
Sync
Section 2
Defines the number of data bits
to be used
ON
 – 8 bits
OFF
 – 7 bits
8 bits
Section 3
Controls the use of parity
ON
 – Parity enabled
OFF
 – Parity disabled
P.EN
Section 4
Defines the parity type
ON
 – Even parity
OFF
 – Odd parity
Even
Section 5
Defines the number of stop bits ON – One stop bit
OFF
 – Two stop bits
1STB
Section 6
Controls the RTS to DCD
transfer
ON
 – DCD, the DCD signal
turns on when the two units
reach synchronization
OFF
 – CNT, the DCD signal of
the local unit follows the RTS
signal of the remote unit
DCD
Note: The DCD signal is OFF when a digital loopback is active (receiving RLB command) or when there is no
synchronization between the units).