Performing Loopback Tests
139
Performing a Remote
Loopback Test on a
56/64 Kbps CSU/DSU
Module
This section describes how to perform a loopback test on a 56/64 Kbps 
CSU/DSU module.
Figure 12   CSU/DSU Module Loopback Testing
Before running the loopback test, complete the following tasks:
Attach a console or Telnet to your bridge/router.
Cable the CSU/DSU module to the network.
Verify the path and port number of the port you are testing.
The remote loopback test includes remote CSU Loopback and remote 
DSU Loopback.
To perform a remote loopback test, follow these steps:
Set the baud rate of the port. The default setting of the Autobaud feature 
is ON. You can turn off autobaud by setting the baud rate. For example, 
to set the baud rate to 64 Kbps, enter:
SETDefault !3 -PAth BAud=64
To turn on autobaud, enter:
SETDefault !3 -PAth BAud=AUto
Enable the port by entering:
SETDefault !3 -PAth CONTrol=ENable